GigHz Precision AI Precision AI

Documentation › Reference

Release notes

Applies to GigHz Precision AI v13.35.6 · Last reviewed 2026-10-13 · Questions: signal@gighz.com

The version running now is 13.35.6. Internal fixes and test-suite changes are not listed; behaviour a radiologist would notice is.

13.3x series (September and October 2026)

  • Live placement keeps working at full speed while the browser tab is behind PACS.
  • Fragments split by a pause ("7 mm right." + "hepatic lobe cyst.") are re-joined before placement; the transcriber's own periods are no longer trusted as sentence ends.
  • Editing the transcript offers a live rebuild of the whole report instead of re-placing edited lines on top of the old ones.
  • Impression policy: incidental findings (simple atelectasis, unchanged degenerative change, hardware, simple cysts, vascular calcification, diverticulosis, artifact statements) are kept out of composed impressions unless escalated or unless they answer the indication.
  • Near-duplicate sentences (a tense or typo variant of a line already placed) no longer appear twice.
  • Multiphase liver and adrenal washout protocols now fill live.
  • A named vessel finding that would have been parked is redirected to its vessel line through every path.
  • The blank line between the impression and the patient-information paragraph is preserved.
  • Nightly quality assurance moved to the production environment; paid corpus replay weekly, deterministic checks nightly.

13.2x series (August and September 2026)

  • Production moved to a single-tenant AWS environment with direct TLS, vendored libraries and no third-party scripts.
  • Self-serve signup with email verification, the Terms ceremony, institutional and card trials, attending and trainee prices, and automatic trainee-rate handling after graduation.
  • Onboarding email and the illustrated Getting started guide.
  • Silence fillers invented by the transcriber during pauses are discarded.
  • Incidental benign findings no longer lead an impression above a real finding; grouping and ranking apply to generated reports as well as live ones.
  • A placement-service outage parks findings with a warning and never composes an impression from unplaced text.
  • A public health probe lets the nightly tests confirm the live site is configured.

13.1x series (summer 2026)

  • Live report fill with the simple live-fill bases, the live impression draft, the switch-template-mid-fill control, and the structured template editor behind Make it mine.
  • One implementation per clinical scoring system, shared by the live panel, voice macros and generated reports; Bosniak 2019 and LI-RADS v2018 grids verified against worked cases.
  • Feedback payload made metadata-only.
  • Fragment coalescing, dangling-tail joins and multi-finding lines.

This page is generated from documentation that ships with the application (docs v1.2.2). Version numbers, prices and trial lengths on this page are read from the running system, not typed by hand.